Cytiva product datasheets, catalogs, app notes
-
Epitope Binning: A Critical Step In Antibody Selection
1/31/2020
Epitope binning immunoassays using surface plasmon resonance (SPR) can and should be deployed in the development of new potential drug candidates. This article discusses how SPR is used to characterize closely related “bins” of mAbs targeting the same epitope of the target protein and how the selection process is used to develop new vaccines, therapeutic antibodies, and diagnostic tools.
-
EDGE Confocal Imaging Technology
10/9/2019
Increasingly, scientists are being challenged to study more biologically-relevant model systems, and this often means imaging thick, demanding 3D samples that may also be alive. Read how IRIS and EDGE confocal imaging can offer high contrast imaging of thicker samples.
-
An End-To-End, Semi-Continuous Process For mAb Production
9/22/2019
See how the different unit operations in a laboratory-scale monoclonal antibody (mAb) process can be connected and integrated into a semi-continuous process.
-
Quantitating Binding Similarities In IgG Fcγ Receptor Analysis
5/23/2019
Critical quality attributes are fundamental to regulatory compliance in drug development and manufacturing. Learn how surface plasmon resonance has been applied for protein characterization of antibody effector function.
-
Converting From ELISA To Biacore SPR Assays
3/27/2019
This article provides general guidance on how to convert an existing ELISA assay to a Biacore SPR-assay and, by doing so, shows how you can get results in less than half the time compared with ELISA.
-
Adenovirus Production In Single-Use Bioreactor System
3/8/2019
Rocking bioreactor systems can shorten the seed train prior to inoculation and provide optimized growth conditions for sensitive cells. This study presents a robust production of adenovirus using such a system.
-
Multidimensional Scale-Up Of A mAb Capture Step Contributes To Shortened Time To Market
10/10/2018
This application note demonstrates a multidimensional scale-up (change of both column diameter and bed height) of a mAb capture step, using the ÄKTA pilot 600 chromatography system.
-
Process-Economy Simulation Of mAb Capture Step With Protein A Chromatography Resin
10/10/2018
Calculation examples that highlight scenarios where the enhanced capacity and alkaline‑stability of MabSelect PrismA can provide process economic benefits to large‑scale mAb processing.
-
Use Of Sodium Hydroxide For Cleaning And Sanitization Of Chromatography Resins And Systems
10/2/2018
This application note examines these aspects of using sodium hydroxide as a cleaning and sanitizing agent.
-
Capacity And Performance Of MabSelect™ PrismA Protein A Chromatography Resin
10/2/2018
This application note demonstrates the binding capacity of MabSelect PrismA in comparison with its predecessor products for both polyclonal and monoclonal antibodies.